ONDECK
Academy
OOW Oral Prep
Module 08 — OOW 3000 GT Oral Preparation
LSA & Fire
Fire classes & extinguishing agents · LSA equipment · EPIRB · SART · Immersion suits · Drills · Abandon ship
Fire — The Triangle and Classes
Fire requires three elements: Fuel (combustible material) + Heat (ignition source) + Oxygen. Remove any one element and the fire is extinguished. Every firefighting method works by removing one of these.
ClassFire typeCorrect agentNever use
Class ASolid materials — wood, fabric, paper, plasticsWater, foam, dry powder (CO₂ knocks flame down but does not cool — expect re-ignition)—
Class BFlammable liquids — fuel, oil, paint, solventsFoam, dry powder, CO₂Water jet — spreads the fire
Class CFlammable gases — LPG, acetyleneIsolate the supply first; dry powder. Water spray only to cool cylinders and surroundingsWater jet or foam on the flame
Class DFlammable metals — magnesium, lithiumDry sand or specialist dry powder onlyWater (violent reaction)
Class F / KCooking oils and fatsWet chemical extinguisherWater — violent steam explosion
ElectricalEnergised electrical equipmentCO₂ or dry powder — non-conductiveWater or foam — conductor
Portable Extinguishers — Quick Reference
TypeColourHow it worksBest for
WaterRedCooling — removes heatClass A only
Foam (AFFF)Red / cream panelSmothers — removes oxygen; coolsClass A and B
CO₂Red / black panelSmothers — displaces oxygenElectrical, Class B — switchboards, engine rooms (not deep-fat fryers)
Dry Powder (ABC)Red / blue panelChemical chain reaction interruptionClass A, B, C — versatile but messy, impairs visibility
Wet ChemicalRed / yellow panelSaponification — reacts with cooking oils to form a soap layerClass F — galley cooking fires only
Fixed Fire Suppression Systems
CO₂ System (Engine Room / Paint Store)
  • Floods the space with CO₂ — displaces oxygen
  • All personnel must be evacuated before activation
  • Ventilation must be stopped — close dampers and fans
  • Space must not be re-entered until CO₂ has cleared and O₂ level confirmed safe
  • Two separate controls for release (FSS Code) prevent accidental activation, and an audible and visual pre-discharge alarm clears the space first
Water Mist / Sprinkler
  • Cools and smothers — fine water droplets absorb heat and reduce oxygen
  • Lower water volume than conventional sprinkler
  • Effective on Class A and B fires
  • Does not damage equipment as severely as flood systems
  • Common in accommodation and machinery spaces on superyachts
Drills — Requirements SOLAS III
Drill typeFrequencyNotes
Abandon Ship / Lifeboat drillMonthly — every crew member. Each lifeboat launched with its crew and manoeuvred in the water at least every 3 monthsWithin 24 hours of leaving port if more than 25% of crew have not taken part in abandon ship and fire drills on that vessel in the previous month
Fire drillMonthly — every crew member, as well as (not instead of) the abandon ship drillFire party to demonstrate use of equipment — breathing apparatus, hose, extinguisher
Rescue boatLaunched with its crew and manoeuvred monthly where reasonable and practicable — at least every 3 monthsPart of the abandon ship drill programme
Enclosed space entry and rescue drillAt least every 2 months (SOLAS III/19)Includes checking and using the PPE, gas-detection and rescue equipment
GMDSS communications testDaily / Weekly / Monthly tests as per scheduleDSC test call, EPIRB self-test, SART test
Emergency steering drillAt least every 3 months (SOLAS V/26)Direct control from the steering gear compartment, communications with the bridge and, where fitted, the alternative power supply — officers concerned must know the changeover
NEW CREW: Every crew member with emergency duties must know them before the voyage begins, and new joiners get on-board training in the ship's life-saving appliances as soon as possible and within two weeks of joining. If more than 25% of the crew have not taken part in drills aboard in the previous month, abandon-ship and fire drills are held within 24 hours of leaving port. This is not optional — it is a SOLAS requirement.
Life-Saving Appliances — Key Equipment
EquipmentFunctionKey facts
EPIRB
Emergency Position Indicating Radio Beacon
Transmits a distress signal on 406 MHz to the COSPAS-SARSAT satellite system — identifies vessel and position — plus a 121.5 MHz homing signal. Float-free EPIRBs installed on or after 1 July 2022 (MSC.471(101)) also carry a GNSS receiver and an AIS locating signalRegistered to the vessel — registration must be kept current. Float-free bracket — the hydrostatic release unit (HRU) frees it at ~1.5–4 m depth (before 4 m) and it activates automatically once floating free. Manual activation available. HRU replaced by its expiry date if disposable (typically 2 years), or serviced at intervals not exceeding 12 months if not (SOLAS III/20.9). EPIRB tested at least every 12 months for all aspects of operational efficiency, with shore-based maintenance at intervals not exceeding 5 years (SOLAS IV/15.9)
SART
Search and Rescue Transponder
When activated, responds to 9 GHz (3cm) radar — creates a line of 12 dots on the rescuing vessel's radar display along the SART's bearing — the dot nearest own ship marks the SART, and the line extends outward beyond itIMO performance standard: works at least 5 nm from a ship's radar with its scanner 15 m up, and up to 30 nm from an aircraft radar at 3,000 ft. Battery life minimum 96 hours on standby / 8 hours activated. Hold vertically — optimal signal. AIS-SARTs now also used — transmit GPS position via AIS
Immersion SuitThermal protection in cold water — reduces heat loss, extends survival timeMust be donned within 2 minutes — practice is essential. Must fit over clothing. Covers the entire body except the face. Some suits are designed to be worn with a lifejacket, others have the buoyancy built in — know which yours are. Practised in drills and on-board training
LifejacketKeeps the wearer face-up with the airway clear of waterSOLAS performance standard (LSA Code 2.2), not a Newton rating: buoyancy not reduced by more than 5% after 24 hours in fresh water ("150N" is an ISO 12402 leisure rating). Self-righting — turns an unconscious person face-up. Light and whistle mandatory. Inflatable lifejackets serviced at intervals not exceeding 12 months (SOLAS III/20.8). Every strap done up — including the crotch or thigh strap where fitted (the LSA Code sets performance; it does not require a crotch strap by name)
LiferaftInflatable survival platform for crew and passengersHydrostatic release — float-free activation at ~1.5–4 m depth (before 4 m). Painter line — secure to vessel before deploying. Equipped with SOLAS pack: water, rations, flares, bailer, knife, pump. Serviced every 12 months at an approved station (the flag may extend this to 17 months)
Rescue BoatFast craft for recovering persons from the water and conducting SAR operationsStowed in continuous readiness for launching in not more than 5 minutes. Crew must be able to launch and recover at sea. Must have: engine, compass, first aid, tow line, fire extinguisher, searchlight
PyrotechnicsVisual distress signalsParachute rocket flares — red, rise to at least 300 m, burn at least 40 seconds (LSA Code 3.1; no visibility range is set). Handheld flares — red, burn at least 1 minute. Buoyant orange smoke — at least 3 minutes, day use, best in light winds. Expiry date — must be in date or disposed of correctly
Abandon Ship Sequence
Do not abandon ship until the Master orders it — the vessel is the best liferaft until it is no longer safe to remain on board.
Action
1. Master orders abandon ship — by voice, over the PA. Seven or more short blasts + one long is the general emergency alarm: the MUSTER signal, not the order to abandon
2. Send Mayday with position if not already done — activate EPIRB
3. All persons don lifejackets and immersion suits
4. Muster at assigned stations — account for all persons
5. Launch survival craft — liferafts to leeward if possible
6. Take SART, portable VHF, flares, water, medication into survival craft
7. Cut painter line only when all have boarded and are clear of the vessel
8. Move well clear of the vessel — suction risk as vessel sinks
9. Activate SART and maintain VHF watch on Ch 16
Agent Selection — The Triangle Applied, Not Recited
FireAttackNeverWhy
Class A (solids — bedding, linings)Water — cooling wins—Heat is the leg to remove
Class B (fuels, oils)Foam blanket, CO2, powderWater jetThe jet spreads burning fuel; foam smothers
Live electricalIsolate FIRST, then CO2Water while liveIsolation converts it into an ordinary fire
Class F (galley oils)Fire blanket, wet chemicalWater — everA cup of water flash-boils into ~1,700 volumes of steam and throws burning oil
Lithium battery runawaySustained WATER cooling, isolation to open deckRelying on smotheringThe cell makes its own heat and oxygen — only heat removal stops the chain; expect re-ignition for hours
The examiner marks the reasoning, not the list: water is a HEAT weapon, CO2 and foam are OXYGEN weapons, isolation takes away the FUEL — or, on a live electrical fire, the source of HEAT. Answer from the triangle and every agent question answers itself — including the ones you haven't been asked yet.
The Fixed CO2 Flood — Sequence and the Sealed-Space Discipline

Engine-room fire beyond first response: muster and head-count — absolute, because the end of this sequence is flooding a space with gas that kills; fuel quick-closing valves shut; ventilation stopped, flaps and dampers sealed; head-count confirmed AGAIN; the master releases. Then the part that saves the ship: the space stays shut for hours — read the fire through boundary temperatures from outside, boundary-cool the adjacent bulkheads and the deck above, and re-enter only cooled, ventilated, risk-assessed, with BA teams and charged hoses. Cracking the door "for a look" at thirty minutes vents your only agent onto hot fuel that relights — and there is no second charge.

BA Control — The Board That Keeps Rescuers Alive

Nobody enters a smoke-filled space without the system around them: the entry control board — names, cylinder pressures, time in, whistle time calculated — run by a dedicated controller; a dressed back-up team before the first team enters; door discipline (read it, crack it against your weight, cool the gas layer with short pulses before advancing); and comms on a schedule so silence itself is an alarm. The arithmetic is unforgiving: a 300-bar set at heavy work gives twenty-something minutes, and the whistle margin is the exit, not the reserve. On a yacht with one BA team, the honest consequence: no relief team may mean the attack waits for the fixed system — a decision, not a failure.

LSA Numbers That Get Asked Cold
ItemThe figure
Liferaft HRUFires at ~1.5–4 m depth; serviced/replaced per its expiry (typically 2 years); the painter's weak link parts AFTER inflation
Liferaft serviceAnnual, at an approved station (extensions per flag rules)
Immersion suit donning2 minutes, drilled, unaided
Lifejacket lights≥8 hours' operation; whistle attached
EPIRB406 MHz to Cospas-Sarsat; ≥48 h transmission; battery and HRU dates in the planned maintenance; registration current — the RCC acts on what the database says
SART96 h standby / 8 h active; X-band only; mount ≥1 m above sea level in the craft
PyrotechnicsRocket parachute flares, hand flares, buoyant smoke — in date, stowage known, disposal via proper channels
General emergency alarmSeven or more short blasts + one long — the MUSTER signal; abandon ship is the master's VERBAL order, never an alarm alone
Cold Water — The 1-10-1 Clock Behind Every Drill

One minute of cold shock — the involuntary gasp that drowns unprotected airways before hypothermia is even relevant; ten minutes of meaningful movement before cold incapacitation strips grip and swimming; roughly one hour to unconsciousness — which means you PERSIST: he's cold, not dead. Recovery doctrine follows the physiology: flotation to him while his hands still work, horizontal-ish recovery where practicable (circum-rescue collapse is real — cold hearts arrest on rough vertical handling), gentle movement, insulate, monitor, treat as a casualty even if he's talking. This clock is why MOB drills are timed in minutes, why lifejackets that right an unconscious wearer matter, and why the suit-versus-jacket answer is "both — one buys the airway, the other buys time."

Additional Question

Walk me around your vessel's fire plan — what is it, where is it, and who is it actually for?

The fire and safety plan shows every fire boundary, detection zone, extinguishing system, extinguisher, BA set, escape route and remote shut-off aboard — posted where the crew work, and a copy in a prominently marked weathertight enclosure OUTSIDE the deckhouse. That external copy answers the 'who for': it's for the SHORE fire brigade who board a burning vessel knowing nothing — their first act is pulling that plan. Aboard, it's the attack team's map and the induction tool for new crew. And the follow-up I'd expect: I should be able to stand at my muster station and point to the nearest hydrant, extinguisher, BA set and two escape routes without looking at the plan — that's what familiarisation signed off.
Oral Exam Practice Questions
Question 1

What class of fire is a fuel oil fire and what do you use to extinguish it?

Class B — flammable liquid. Extinguish with foam (AFFF), CO₂, or dry powder. Never use a water jet on a Class B fire — it will spread the burning liquid and intensify the fire (water mist and fog systems are designed for it; a jet is not). In the engine room, if first response fails, I would use the fixed CO₂ system — but only after confirming all personnel are evacuated and ventilation is shut down.
Question 2

What is an EPIRB and how does it work?

An Emergency Position Indicating Radio Beacon. When activated it transmits a distress signal on 406 MHz to the COSPAS-SARSAT satellite system. The signal carries the beacon's unique coded identity — usually based on the MMSI — which the RCC looks up in the registration database, and, where it has a GNSS receiver, its position; the satellites can also locate it independently. It also transmits a 121.5 MHz homing signal. The EPIRB must be registered to the vessel and the registration kept current — an unregistered EPIRB is useless. It has a float-free bracket with a hydrostatic release unit that frees it at about 1.5–4 metres depth, before 4 metres; it activates automatically once floating free. Manual activation is also available. The EPIRB is self-tested to the manufacturer's schedule (commonly monthly), tested for all aspects of operational efficiency at least every 12 months, and given shore-based maintenance at intervals not exceeding five years (SOLAS IV/15.9); the battery is replaced at the manufacturer's interval — typically around five years — and the HRU is replaced by its expiry date, typically every two years.
Question 3

What are the drill requirements under SOLAS?

Every crew member takes part in one abandon ship drill and one fire drill every month. Each lifeboat launched and manoeuvred in the water — at least every three months. Enclosed space entry and rescue drill — at least every two months. Drills within 24 hours of leaving port if more than 25% of the crew have not taken part in drills aboard in the previous month; new joiners trained on the ship's life-saving appliances within two weeks of joining. Emergency steering drill — at least every three months. All drills must be recorded in the log.
Question 4

What is a SART and how is it used by the rescue vessel?

A Search and Rescue Transponder. When activated it responds to 9 GHz radar transmissions from search vessels or aircraft. On the rescuing vessel's radar screen it creates a line of 12 equally spaced dots — the first dot is at the SART position and the line extends away from the rescue vessel. Hold the SART vertically for the best signal. The IMO standard is detection at least 5 nm from a ship's radar with its scanner 15 m up, and up to 30 nm from an aircraft at 3,000 ft — mount it at least 1 m above the sea. Battery life is 96 hours on standby and 8 hours when activated.
Question 5

Engine room fire — what are your immediate actions?

Sound the general alarm — seven or more short blasts followed by one long. Call the Master. Stop ventilation to the engine room — close all fans and dampers. Close the fire door. Account for all engine room personnel — confirm everyone is out. If the fire cannot be fought with portable extinguishers, prepare to release the fixed CO₂ system — but only after confirming all personnel are clear. Alter course to put the fire downwind. Send Mayday if vessel safety is threatened. Prepare for abandon ship if the fire cannot be controlled.